The device uses a Siemens PLC as its controller, automatically collecting current data in real time. Based on the configured parameters, it automatically controls the external step-up and step-down motors to stabilize the current data. The device also records and saves the actual current data to a USB flash drive and can communicate with a host computer to upload real-time data. What are the testing standards for air conditioner temperature rise current measurement and control recorders? Guangzhou Zhipinhui Electronic Technology Co., Ltd. explains.

1. Input Current: 3 channels
0.3A to 6A per channel
Internal load resistance: ≤0.2Ω, temperature coefficient ≤100 PPM
2. Input range: 4 manually selectable ranges
Current transformers require external user configuration
100A range: 10A-180A
10kA range: 0.15kA-1.8kA
10kA range: 1.5kA-18kA
100kA range: 10kA-180kA
3. Current measurement: Digital display, accuracy 1% + 2 digits
True RMS measurement
Internal measurement linearity ≤1%
Excluding external current transformer nonlinearity
Calibration coefficients can be entered for each channel and range
4. Measurement and Control Interface: Touchscreen Operation
Output Control: 3 Channels
A. Two long-life solid-state relay ports (both ramp-up and ramp-down) per channel for faster control and longer life
B. Load capacity of the ramp-down and ramp-down output solid-state relays: AC480V 10A
C. User External Connections: Overload and short-circuit protection, motor limit switches
D. Control Cycle: 1 second
E. Start and Stop Buttons: Control test start and stop
F. Test Time: 0.01 to 99.99 hours, automatically stops upon expiration