                                                          RX9916 Thermostat (Thermal Cut-off) Temperature Life Test Bench I. Overview: This equipment is designed to conduct life tests on thermal cut-offs in accordance with the standards for durability or life tests of thermal cut-offs and thermal circuit breakers in GB4943.1-2011 Information Technology Equipment Safety - Part 1: General Requirements: Appendix K.5, GB14536.1-2008, GB19212.1-2008 and other relevant standards. The equipment can automatically reset and perform tests automatically. II. Main Technical Parameters: 1. Equipment Power Supply: AC220V, 50/60Hz, 10KVA 2. Number of Test Stations: 1 station   Applicable Products: Thermal cut-offs/thermal circuit breakers, applicable for both normally closed and normally open types, compatible with manual reset and automatic reset, and the rated current does not exceed 20A. 3. ※ Controlled by a Chinese PC terminal + self-developed programming software. The test process is controlled by the program, and it can intelligently judge the test status, and precisely control the temperature and current output. It supports exporting test data in the form of EXCEL spreadsheets for subsequent data processing and analysis. 4. ※ Computer Configuration: 19-inch integrated liquid crystal touch screen computer: 1.8G dual-core CPU, 2G memory, 64G solid-state drive, and Windows 7 Chinese operation system. 5. ※ Temperature Characteristic Mode: ① ※ Supports four modes of sample testing: ON test, OFF test, ON-OFF test, and OFF-ON test; ② Temperature Range: 50~250℃; ③ Medium Used: Aluminum alloy heating block + contact heating; ④ ※ In any working mode state, multiple cycle tests can be set. 6. ※ Load Life Mode: ① ※ Equipped with a load module independently developed by our company: It can be controlled by the program to directly apply the load to the test sample for load life testing; ② Temperature Range: 50~250℃; ③ Medium Used: Aluminum alloy heating block + contact heating; ④ Load Parameters Required for Life Load: A、※ Test Voltage: Can be set from 100V~250V, with a display accuracy of 1% B、※ Test Current: Can be set from 1A~20A

右侧面D.png


                                               RX9916 Thermostat (Thermal Cut-off) Temperature Life Test Bench I. Overview: This equipment is designed to conduct life tests on thermal cut-offs in accordance with the standards for durability or life tests of thermal cut-offs and thermal circuit breakers in GB4943.1-2011 Information Technology Equipment Safety - Part 1: General Requirements: Appendix K.5, GB14536.1-2008, GB19212.1-2008 and other relevant standards. The equipment can automatically reset and perform tests automatically. II. Main Technical Parameters: 1. Equipment Power Supply: AC220V, 50/60Hz, 10KVA 2. Number of Test Stations: 1 station   Applicable Products: Thermal cut-offs/thermal circuit breakers, applicable for both normally closed and normally open types, compatible with manual reset and automatic reset, and the rated current does not exceed 20A. 3. ※ Controlled by a Chinese PC terminal + self-developed programming software. The test process is controlled by the program, and it can intelligently judge the test status, and precisely control the temperature and current output. It supports exporting test data in the form of EXCEL spreadsheets for subsequent data processing and analysis. 4. ※ Computer Configuration: 19-inch integrated liquid crystal touch screen computer: 1.8G dual-core CPU, 2G memory, 64G solid-state drive, and Windows 7 Chinese operation system. 5. ※ Temperature Characteristic Mode: ① ※ Supports four modes of sample testing: ON test, OFF test, ON-OFF test, and OFF-ON test; ② Temperature Range: 50~250℃; ③ Medium Used: Aluminum alloy heating block + contact heating; ④ ※ In any working mode state, multiple cycle tests can be set. 6. ※ Load Life Mode: ① ※ Equipped with a load module independently developed by our company: It can be controlled by the program to directly apply the load to the test sample for load life testing; ② Temperature Range: 50~250℃; ③ Medium Used: Aluminum alloy heating block + contact heating; ④ Load Parameters Required for Life Load: A、※ Test Voltage: Can be set from 100V~250V, with a display accuracy of 1% B、※ Test Current: Can be set from 1A~20A



All reviews0

Zhipinhui After-Sales Policy:


*After-Sales Hotline: +864008166687


1. Our company has assembled a team of experienced field engineers and senior technicians to promptly respond

to any equipment issues and provide after-sales maintenance.


2. Within China, within one week of new product delivery, our after-sales technical staff will install the equipment and

provide after-sales training at the customer's location, using the contact information and address provided by the  customer.


3. All complaints related to product quality will be responded to within one hour. Within 3-5 hours within the province,

and within 24-48 hours outside the province, we will arrive at the customer's site,

determine the appropriate action based on the complaint, and provide after-sales repairs. (Domestic)


4. For international travel, our company can also arrange for an after-sales engineer to visit you for installation and

commissioning. Please discuss any travel and catering issues in advance.

We also provide video installation guides for you to choose from, providing you with a comprehensive and multi-faceted solution.


5. Any material costs related to product quality during the warranty period will be borne by our company.


6. During the warranty period, we will provide free repairs due to improper use or environmental factors.

The materials and accessories used for repairs will be charged at cost only.


Build a fully functional high-end laboratory
Book Now